SPECIFICATION |
MODEL |
AD-155A |
AD-155B |
AD-155C |
OUTPUT |
|
|
|
Output number |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
DC voltage |
13.8V |
13.3V |
27.6V |
27.1V |
54V |
53.5V |
Rated Current |
10.5A |
0.5A |
5A |
0.5A |
2.7A |
0.2A |
Current Range |
0~11.5A |
0-0.5A |
0~5.5A |
0-0.5A |
0-2.7A |
0-0.5A |
Rated Power |
151.55W |
151.55W |
156.5W |
Ripple & Noise |
150mVp-p |
-------- |
150mVp-p |
-------- |
240mVp-p |
-------- |
Voltage Adj. Range |
CH1:12~14.5V |
CH1:24~29V |
CH1:48-58V |
Voltage Tolerance |
±2.0% |
-------- |
±1.0% |
-------- |
±1.0% |
-------- |
Line Regulation |
±0.5% |
-------- |
±0.5% |
-------- |
±0.5% |
-------- |
Load Regulation |
±0.5% |
-------- |
±0.5% |
-------- |
±0.5% |
-------- |
Setup, Rise Time |
1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load |
Hold Up Time |
24ms/230VAC 20ms/115VAC at full load |
INPUT |
|
Voltage Range |
88~264VAC 47~63Hz; 124~370VDC |
AC Current |
2.5A/115VAC 1.5A/230VAC |
Efficiency |
80% |
84% |
84% |
Inrush Current |
Cold start 20A/115VAC 40A/230VAC |
Leakage Current |
<1mA /240VAC |
PROTECTION |
|
Over Load |
CH1:105 ~ 135% CH2:0.51 ~ 0.9A rated output power |
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse |
Over Voltage |
CH1:15.87~18.63V |
CH1:31.74~37.26V |
CH1:62.1 ~ 72.9V |
Protection type:Shut down o/p voltage, re-power on to recover |
Battery Low |
10V±0.8V |
19.5V(+1.5V,-1V ) |
39V±2V |
ENVIRONMENT |
|
Working Temp. |
-10~+60ºC (Refer to "Derating Curve") |
Working Humidity |
20~90%RH non-condensing |
Storage Temp., Humidity |
-20~+85ºC,10~95%RH |
Temp. Coefficient |
±0.03%/ ºC(0~50ºC ) |
Vibration |
10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes |
SAFETY &EMC |
|
Safety Standards |
UL60950-1, TUV EN60950-1 |
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
Isolation Resistance |
I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25ºC /70%RH
|
EMC Emission |
Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 |
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A |
OTHERS |
|
Dimension |
199*110*50mm (L*W*H) |
Weight |
0.88Kg |
Packing |
16pcs/carton/15kg/0.95CUFT |
NOTE |
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |