SPECIFICATION | |||||
OUTPUT | |||||
Model | LRS-150-12 | LRS-150-15 | LRS-150-24 | LRS-150-36 | LRS-150-48 |
DC Voltage | 12V | 15V | 24V | 36V | 48V |
Rated Current | 12.5A | 10A | 6.5A | 4.3A | 3.3A |
Current Range | 0~12.5A | 0~10A | 0~6.5A | 0~4.3A | 0~3.3A |
Rated Power | 150W | 150W | 156W | 154.8W | 158.4W |
Ripple & Noise | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p |
Voltage Adj. Range | 10.2~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
Voltage Tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise Time | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||
Hold Up Time | 40ms/230VAC 35ms/115VAC at full load | ||||
Voltage Range | 85 ~ 132VAC / 170 ~264VAC 240 ~ 370VDC(switch on 230VAC) | ||||
Frequency Range | 47 ~ 63Hz | ||||
Efficiency | 87.5% | 88.5% | 89% | 89% | 90% |
AC Current | 2.8A/115VAC 1.6A/230VAC | ||||
Inrush Current | Cold start 60A/230VAC | ||||
Leakage Current | <0.75mA / 240VAC | ||||
Over Load | 110 ~ 140% rated output power | ||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||
Over Voltage | 13.8 ~ 16.2V | 18.75~21.75V | 28.8 ~ 33.6V | 41.4~48.6V | 55.2~ 64.8V |
Protection type: shut down o/p voltage, re-power on to recover | |||||
Working Temp. | -30 ~ +70ºC (Refer to "derating curve") | ||||
Working Humidity | 20 ~ 90% RH non-condensing | ||||
Storage Temp., Humidity | -40 ~ +85ºC, 10 ~ 95% RH | ||||
Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | ||||
Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
Safety Standards | UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved | ||||
Withstand Voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | ||||
EMC Emission | Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN61000-3-2,-3 class A, EN61000-3-3 | ||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A | ||||
Dimension | 159*97*30mm (L*W*H) | ||||
Weight | 0.48Kg | ||||
Packing | 30pcs/carton/15.4kg/0.75CUFT | ||||
NOTE | |||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |