SPECIFICATION |
|
OUTPUT |
|
Model |
NES-35-5 |
NES-35-12 |
NES-35-15 |
NES-35-24 |
NES-35-48 |
DC Voltage |
5V |
12V |
15V |
24V |
48V |
Rated Current |
7A |
3A |
2.4A |
1.5A |
0.8A |
Current Range |
0 ~ 7A |
0 ~ 3A |
0 ~ 2.4A |
0 ~ 1.5A |
0 ~ 0.8A |
Rated Power |
35W |
36W |
36W |
36W |
38.4W |
Ripple & Noise |
80mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
240mVp-p |
Voltage Adj. Range |
4.75 ~ 5.5V |
10.8 ~ 13.2V |
13.5 ~ 16.5V |
21.6 ~ 26.4V |
43.2 ~ 52.8V |
Voltage Tolerance |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Setup, Rise Time |
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load |
Hold Up Time |
50ms/230VAC 10ms/115VAC at full load |
|
|
INPUT |
|
Voltage Range |
85 ~ 264VAC 120 ~ 370VDC |
Frequency Range |
47 ~ 63Hz |
Efficiency |
78% |
81% |
83% |
85% |
86% |
AC Current |
0.75A/115VAC 0.5 A/230VAC |
Inrush Current |
Cold Start 45A |
Leakage Current |
<2mA / 240VAC |
|
|
PROTECTION |
|
Over Load |
110 ~ 150% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage |
5.75~6.75V |
13.8~16.2V |
17.25~20.25V |
27.6~32.4V |
55.2~64.8V |
Protection type: Shut down o/p voltage, re-power on to recover |
|
|
ENVIRONMENT |
|
Working Temp. |
-20 ~ +60ºC (Refer to "Derating Curve") |
Working Humidity |
20 ~ 90% RH non-condensing |
Storage Temp., Humidity |
-40 ~ +85ºC, 10 ~ 95% RH |
Temp. Coefficient |
±0.03%/ºC (0 ~ 45ºC) |
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
|
|
SAFETY & EMC |
|
Safety Standards |
UL60950-1, CB(IEC60950-1),CCC GB4943 approved |
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH |
EMC Emission |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
EMC Immunity |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, EN55024, EN61000-6-1, light industry level, criteria A |
|
|
OTHERS |
|
Dimension |
99*97*36mm (L*W*H) |
Weight |
0.36Kg |
Packing |
45pcs/17.2Kg/0.93CUFT |
|
|
NOTE |
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
3. Tolerance: includes set up tolerance, line regulation and load regulation. |
4. Line regulation is measured from low line to high line at rated load. |
5. Load regulation is measured from 0% to 100% rated load. |
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |