Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
2 year warranty
SPECIFICATION |
|||||
OUTPUT |
|||||
Model |
NES-25-5 |
NES-25-12 |
NES-25-15 |
NES-25-24 |
NES-25-48 |
DC Voltage |
5V |
12V |
15V |
24V |
48V |
Rated Current |
5A |
2.1A |
1.7A |
1.1A |
0.57A |
Current Range |
0 ~ 5A |
0 ~ 2.1A |
0 ~ 1.7A |
0 ~ 1.1A |
0 ~ 0.57A |
Rated Power |
25W |
25.2W |
25.5W |
26.4W |
27.36W |
Ripple & Noise |
80mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
240mVp-p |
Voltage Adj. Range |
4.75~5.5V |
10.8~13.2V |
13.5~16.5V |
21.6~26.4V |
43.2~52.8V |
Voltage Tolerance |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Setup, Rise Time |
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load |
||||
Hold Up Time |
50ms/230VAC 10ms/115VAC at full load |
||||
INPUT |
|||||
Voltage Range |
85 ~ 264VAC 120 ~ 370VDC |
||||
Frequency Range |
47 ~ 63Hz |
||||
Efficiency |
78% |
83% |
84% |
86% |
86% |
AC Current |
0.55A/115VAC 0.35A/230VAC |
||||
Inrush Current |
Cold Start 45A |
||||
Leakage Current |
<2mA / 240VAC |
||||
PROTECTION |
|||||
Over Load |
110 ~ 150% rated output power |
||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||||
Over Voltage |
5.75~6.75V |
13.8~16.2V |
17.25~20.25V |
27.6~32.4V |
55.2~64.8V |
Protection type: Shut down o/p voltage, re-power on to recover |
|||||
ENVIRONMENT |
|||||
Working Temp. |
-20 ~ +60ºC (Refer to "Derating Curve") |
||||
Working Humidity |
20 ~ 90% RH non-condensing |
||||
Storage Temp., Humidity |
-40 ~ +85ºC, 10 ~ 95% RH |
||||
Temp. Coefficient |
±0.03%/ºC (0 ~ 45ºC) |
||||
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
||||
SAFETY & EMC |
|||||
Safety Standards |
Design refer to UL60950-1, CB(IEC60950-1),CCC GB4943 |
||||
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH |
||||
EMC Emission |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
||||
EMC Immunity |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, EN55024, EN61000-6-1, light industry level, criteria A |
||||
OTHERS |
|||||
Dimension |
99*82*35mm (L*W*H) |
||||
Weight |
0.3Kg |
||||
Packing |
45pcs/14.5Kg/0.66CUFT |
||||
NOTE |
|||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |