Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 15.3/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SPECIFICATION | ||||||
Model | LRS-200-5 | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 |
DC Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Current | 40A | 17A | 14A | 8.8A | 5.9A | 4.4A |
Current Range | 0~40A | 0~17A | 0~14A | 0~8.8A | 0~5.9A | 0~4.4A |
Rated Power | 200W | 204W | 210W | 211.2W | 212.4W | 211.2W |
Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
Voltage Adj. Range | 4.5 ~ 5.5V | 10.2~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
Voltage Tolerance | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise Time | 1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load | |||||
Hold Up Time | 16ms/230VAC 12ms/115VAC at full load | |||||
Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC) | |||||
Frequency Range | 47 ~ 63Hz | |||||
Efficiency | 87% | 87.50% | 88% | 89.50% | 89.50% | 90% |
AC Current | 4A/115VAC 2.2A/230VAC | |||||
Inrush Current | Cold start 60A/115VAC 60A/230VAC | |||||
Leakage Current | <2mA / 240VAC | |||||
Over Load | 110 ~ 140% rated output power | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
Over Voltage | 5.75~6.75V | 13.8 ~ 16.2V | 18~21V | 28.8 ~ 33.6V | 41.4~46.8V | 55.2~ 64.8V |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
Over temperature | Hiccup mode, recovers automatically after fault condition is removed | |||||
Working Temp. | -25 ~ +70ºC (Refer to "derating curve") | |||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||
Storage Temp., Humidity | -40 ~ +85ºC, 10 ~ 95% RH | |||||
Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | |||||
Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||
Safety Standards | UL60950-1 approved | |||||
Dimension | 215*115*30mm (L*W*H) | |||||
Weight | 0.66Kg | |||||
Packing | 15pcs/carton/10.9kg/0.78CUFT | |||||
warranty | 2 years |