SPECIFICATIONS |
OUTPUT |
Model |
DR-100-12 |
DR-100-15 |
DR-100-24 |
DC Voltage |
12V |
15V |
24V |
Rated Current |
7.5A |
6.5A |
4.2A |
Current Range |
0-7.5A |
0-6.5A |
0-4.2A |
Rated Power |
90W |
97.5W |
100.8W |
Ripple & Noise |
120mVp-p |
120mVp-p |
150mVp-p |
Voltage Adj. Range |
12-15V |
15-18V |
24-29V |
Voltage Tolerance |
±2% |
±1% |
±1% |
Line regulation |
±1% |
±1% |
±1% |
Load regulation |
±1% |
±1% |
±1% |
Setup, Rise Time |
2700ms,80ms/230VAC 2700ms,80ms/115VAC at full load |
Hold Up Time |
50ms/230VAC 18ms/115VAC at full load |
Voltage Range |
85~264VAC 47~63 Hz; 124~370VDC |
AC Current |
1.6A/115V 0.96A/230V |
Efficiency |
87% |
87% |
89% |
Inrush Current |
Cold start 30A/115VAC 45A/230VAC |
Leakage Current |
<1mA/240VAC |
Over Load |
105%~135% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over Voltage |
16-20V |
19-23V |
30-35V |
Protection type: Shut down o/p voltage, re-power on to recover |
Over Temp. |
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
Working Temp., Humidity |
-20ºC~+60ºC; 20%~90% RH non-condensing |
Storage Temp., Humidity |
-40ºC~+85ºC; 10%~95%RH |
Vibration |
10~500Hz, 2G 10min./1cycle, 60min, each along X, Y, Z axes |
Withstand Voltage |
I/P-O/P: 3KVAC |
Isolation Resistance |
I/P-O/P>100M Ohms / 500VDC/25ºC/70%RH |
Safety Standard |
Design refer to UL60950-1,TUV EN60950-1, EN50178 |
EMC Standard |
EN61240-3,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2, EN61204-3,heavy industry level, criteria A |
Dimension |
100*93*56mm(L*W*H) |
Weight |
0.35Kg |
Packing |
36pcs/13.6Kg/0.89CUFT |
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |