Customization: | Available |
---|---|
Output Type: | Dual |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 10/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SPECIFICATIONS | ||||
OUTPUT | ||||
Model | D-50A | D-50B | ||
Output number | CH1 | CH2 | CH1 | CH2 |
DC Voltage | 5V | 12V | 5V | 24V |
Rated Current | 6A | 2A | 6A | 1A |
Current Range | 1-6A | 0.3-2A | 1-6A | 0.2-1A |
Rated Power | 54W | 54W | ||
Ripple & Noise | 50mVp-p | 100mVp-p | 50mVp-p | 100mVp-p |
Voltage Adj. Range | CH1: -5%, +10% | CH1: -5%, +10% | ||
Voltage Tolerance | ±2% | +5%,-8% | ±2% | ±8% |
Setup, Rise, Hold Up Time | 200ms,50ms,20ms at full load | |||
Voltage Range | 85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC | |||
AC Current | 1.3A/115V 0.65A/230V | |||
Efficiency | 73% | 73% | ||
Inrush Current | Cold start 18A/115V 36A/230V | |||
Leakage Current | <0.5mA/240VAC | |||
Over Load | 105%~150% | |||
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed | ||||
Working Temp., Humidity | -10ºC~+60ºC; 20%~90%RH | |||
Storage Temp., Humidity | -20ºC~+85ºC; 10%~95%RH | |||
Temp. Coefficient | ±0.03%/ºC(0~50ºC) | |||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Zaxes | |||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||
Safety Standard | Design refer to UL1012 | |||
EMC Standard | Design refer to FCC Part15 J Conduction | |||
Dimension | 159*97*38mm(L*W*H) | |||
Weight | 0.53Kg | |||
Packing | 24pcs/13.6Kg/0.75CUFT | |||
NOTE | ||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. |