CE Factory direct sales LRS-200-15 single output high quality dc 15v 200w power supply
Features:
AC input range selectable by switch
Withstand 300VAC surge input for 5 second
Protections: Short circuit / Overload / Over voltage/ Over temperature
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High operating temperature up to 70ºC
High efficiency, long life and high reliability
2 years warranty
more efficient, more thinner, less no-load consumption than old series
SPECIFICATION |
OUTPUT |
Model |
LRS-200-3.3 |
LRS-200-5 |
LRS-200-12 |
LRS-200-15 |
LRS-200-24 |
LRS-200-36 |
LRS-200-48 |
DC Voltage |
3.3V |
5V |
12V |
15V |
24V |
36V |
48V |
Rated Current |
40A |
40A |
17A |
14A |
8.8A |
5.9A |
4.4A |
Current Range |
0~40A |
0~40A |
0~17A |
0~14A |
0~8.8A |
0~5.9A |
0~4.4A |
Rated Power |
132W |
200W |
204W |
210W |
211.2W |
212.4W |
211.2W |
Ripple & Noise |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
Voltage Adj. Range |
2.97~3.6V |
4.5 ~ 5.5V |
10.2~ 13.8V |
13.5~18V |
21.6~28.8V |
32.4~39.6V |
43.2~52.8V |
Voltage Tolerance |
±3.0% |
±3.0% |
±1.5% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±2.5% |
±2.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Setup, Rise Time |
1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load |
Hold Up Time |
16ms/230VAC 12ms/115VAC at full load |
|
|
INPUT |
Voltage Range |
90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC) |
Frequency Range |
47 ~ 63Hz |
Efficiency |
83% |
87% |
87.50% |
88% |
89.50% |
89.50% |
90% |
AC Current |
4A/115VAC 2.2A/230VAC |
Inrush Current |
Cold start 60A/115VAC 60A/230VAC |
Leakage Current |
<2mA / 240VAC |
|
|
PROTECTION |
Over Load |
110 ~ 140% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage |
3.8~4.45V |
5.75~6.75V |
13.8 ~ 16.2V |
18~21V |
28.8 ~ 33.6V |
41.4~46.8V |
55.2~ 64.8V |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
Over temperature |
Hiccup mode, recovers automatically after fault condition is removed |
|
|
ENVIRONMENT |
Working Temp. |
-25 ~ +70ºC (Refer to "derating curve") |
Working Humidity |
20 ~ 90% RH non-condensing |
Storage Temp., Humidity |
-40 ~ +85ºC, 10 ~ 95% RH |
Temp. Coefficient |
±0.03%/ºC (0 ~ 50ºC) |
Vibration |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
|
|
SAFETY |
Safety Standards |
UL60950-1 approved |
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH |
|
|
OTHERS |
Dimension |
215*115*30mm (L*W*H) |
Weight |
0.66Kg |
Packing |
15pcs/carton/10.9kg/0.78CUFT |
|
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.










1. Low MOQ: It can meet your promotional business very well
2. OEM/ODM Accepted: We can produce any your design
3. Good Service: We treat clients as friend
4. Good Quality: We have strict quality control system. Good reputation in the market
5. Fast & Cheap Delivery: We have big discount from forwarder (Long contract)
6. Professional Service: From inquiry ->make sample ->start order ->inspecation ->delivery