20W Single Output Din Rail Power Supply
Features:
Universal AC input/ full range
Protections: Short circuit/ Over load/ Over voltage
Cooling by free air convection
Isolation class 2
LED indicator for power on
100% full load burn-in test
2 years warranty
Model |
MDR-20-5 |
MDR-20-12 |
MDR-20-15 |
MDR-20-24 |
OUTPUT |
DC Voltage |
5V |
12V |
15V |
24V |
Rated Current |
3A |
1.67A |
1.34A |
1A |
Current Range |
0-3A |
0-1.67A |
0-1.34A |
0-1A |
Rated Power |
20W |
20W |
20W |
20W |
Ripple & Noise |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
Voltage Adj. Range |
-5%,+10% |
±10% |
±10% |
±10% |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
Setup, Rise, Hold Up Time |
1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load 70ms/230VAC 16ms/115VAC at full load |
INPUT |
Voltage Range |
85 ~ 264VAC 120 ~ 370VDC |
AC Current |
0.88A/115VAC 0.48A/230VAC |
Efficiency |
74% |
84% |
83.50% |
85% |
Inrush Current |
COLD START 35A/115VAC 65A/230VAC |
PROTECTION |
Over Load |
105%~160% |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over Voltage |
115%~135% |
Protection type: Shut down o/p voltage, re-power on to recover |
ENVIRONMENT |
Working Temp., Humidity |
-10°C~+60°C; 20%~90%RH |
Storage Temp., Humidity |
-40°C~+85°C; 10%~95%RH |
Temp. Coefficient |
±0.03%/°C(0~50°C) |
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
SAFETY |
Withstand Voltage |
I/P-O/P: 3KVAC |
Isolation Resistance |
I/P-O/P: 100M Ohms / 500VDC |
STANDARD |
Safety Standard |
Design refer to UL60950-1,TUV EN60950-1,EN50178 |
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3 |
OTHERS |
Dimension |
22.5*90*100mm(L*W*H) |
Weight |
0.2Kg |
Packing |
100pcs/carton |
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |