SPECIFICATIONS | |||
OUTPUT | |||
Model | MS-15-5 | MS-15-12 | MS-15-24 |
DC Voltage | 5V | 12V | 24V |
Rated Current | 3A | 1.3A | 0.7A |
Current Range | 0-3A | 0-1.3A | 0-0.7A |
Rated Power | 15W | 15.6W | 16.8W |
Ripple & Noise | 80mVp-p | 120mVp-p | 150mVp-p |
Voltage Adj. Range | -9%~+10% | ±10% | ±10% |
Voltage Tolerance | ±2% | ±1% | ±1% |
Inlet Stability | ±0.5% | ±0.5% | ±0.5% |
Load Stability | ±1% | ±0.5% | ±0.5% |
Setup, Rise, Hold Up Time | 200s,100ms,30ms at full load | ||
INPUT | |||
Voltage Range | 100~240VAC 47-63Hz; 240~370VDC | ||
AC Current | 0.5A/115V 0.25A/230V | ||
Efficiency | 76% | 78% | 80% |
Inrush Current | Cold-start current 15A/115V 30A/230V | ||
Leakage Current | <0.5mA/240VAC | ||
PROTECTION | |||
Over Load | 105%~150% rated output power | ||
Protection type: Fold back current limiting Reset: auto recovery | |||
Over Voltage | ...... | ||
Over Temp. | ...... | ||
ENVIRONMENT | |||
Working Temp., Humidity | -10ºC~+60ºC(Refer to output derating curve), 20%~90%RH | ||
Storage Temp., Humidity | -20ºC~+85ºC,10%~95% RH non-condensing | ||
Temp. Coefficient | ±0.02%/ºC(0~50%) | ||
Vibration | 10~500Hz,2G 10min,/1cycle,Period for 60min,each axes | ||
SAFETY | |||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||
STANDARD | |||
Safety Standard | Meet UL1012 requirement | ||
EMC Standard | Meet EN55022, class A | ||
OTHERS | |||
Dimension | 84*58*38mm(L*W*H) | ||
Weight | 0.2Kg | ||
NOTE | |||
1.The testing condition for the parameter above is: 230VAC input, rated load, 25ºC 70% RH.Humidity. 2.Error.include the setting error,line stability and load stability. 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF & 47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. |