factory outlet Uninterrupted Power Supply RoHS CE 50w 27.6v UPS Function power supply for power failure
50W Single Output UPS function Power Supply SCP-50 series
Product Description
Features:
Universal AC input/Full rangProtection: Short circuit / Overload / Over voltage / battery polarity protections(by fuse)Cooling by free air convectionLED indicator for power onNo load power consumption<1WSuitable for installation in metallic or non-metallic system enclosure100% full load burn-in test2 years warranty
SPECIFICATION |
OUTPUT |
|
Model |
SCP-50-12 |
SCP-50-24 |
DC Voltage |
13.8V |
27.6V |
Rated Current |
3.6A |
1.8A |
Current Range |
0-3.6A |
0-1.8A |
Rated Power |
49.7W |
49.7W |
Ripple & Noise |
120mVp-p |
200mVp-p |
Voltage Adj. Range |
+15,-5% |
+15,-5% |
Voltage Tolerance |
±2% |
±1% |
Inlet Stability |
±1% |
±1% |
Load Stability |
±2% |
±1% |
Setup, Rise |
500ms,30ms/230VAC 1200ms,30ms/115VAC at full load |
Hold Up Time |
50ms/230VAC 16ms/115VAC at full load |
Voltage Range |
85~264VAC 120-370VDC |
Frequency Range |
47-63Hz |
AC Current |
1.1A/115VAC 0.65A/230VAC |
Efficiency |
81% |
85% |
Inrush Current |
Cold-start 45A |
Leakage Current |
<2mA/240VAC |
Over Load |
4.3A~5.8A rated output power |
2.2A~2.9A rated output power |
Protection type: hiccup mode,recovers automatically after fault condition is removed |
Over Voltage |
16.6~19.3V |
33.1~38.5V |
Protection type: shut down o/p voltage, re-power on to recover |
Working Temp., Humidity |
-20ºC~+60ºC(Refer to output derating curve),20%~90%RH |
Storage Temp., Humidity |
-40ºC~+85ºC, 10%~95%RH |
Temp. Coefficient |
±0.03%/ºC(0~45ºC) |
Vibration |
10~500Hz,2G 10min,/1cycle,Period for 60min,Each along X.Y.Z axes |
Withstand Voltage |
I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
Safety Standard |
UL60950-1,CCC,CE |
EMC Standard |
EN55022,CLASS B |
Dimension |
129*98*38mm(L*W*H) |
Net Weight |
375.7g |
Packing |
450g/pc 30pcs/carton |