CE MDR-40-24 din rail type SMPS 40W 24V power supply 1.7A
40W Single Output Industrial DIN Rail Power Supply MDR-40 series
Features:
Universal AC input/ full range
Protections: Short circuit/ Over load/ Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
2 years warranty
Product Parameters
SPECIFICATIONS |
OUTPUT |
Model |
MDR-40-5 |
MDR-40-12 |
MDR-40-24 |
MDR-40-48 |
DC Voltage |
5V |
12V |
24V |
48V |
Rated Current |
6A |
3.33A |
1.7A |
0.83A |
Current Range |
0-6A |
0-3.33A |
0-1.7A |
0-0.83A |
Rated Power |
30W |
40W |
40.8W |
39.8W |
Ripple & Noise |
80mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
Line regulation |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Load regulation |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Setup, Rise Time |
500ms,30ms/230VAC 500ms,30ms/115VAC at full load |
Hold Up Time |
50ms/230VAC 25ms/115VAC at full load |
INPUT |
Voltage Range |
85~264VAC 47~63Hz; 120~370VDC |
AC Current |
1.1A/115VAC 0.7A/ 230VAC |
Efficiency |
78% |
86% |
88% |
88% |
Inrush Current |
Cold start 30A/115VAC 60A/230VAC |
Leakage Current |
<1mA/240VAC |
PROTECTION |
Over Load |
105% ~ 150% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over Voltage |
6.27-7.25V |
15.6-18V |
31.2-36V |
57.6-64.8V |
Protection type: Shut down o/p voltage, re-power on to recover |
ENVIRONMENT |
Working Temp., Humidity |
-20ºC~+70ºC; 20%~90% RH non-condensing |
Storage Temp., Humidity |
-40ºC~+85ºC; 10%~95%RH |
Temp. Coefficient |
±0.03%/ºC(0~50ºC) |
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
SAFETY |
Withstand Voltage |
I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-F/G: >100M Ohms / 500VDC/25ºC/70% RH |
STANDARD |
Safety Standard |
Design refer to UL508,TUV EN60950-1 |
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-1,EN61204-3, heavy industry level, criteria A |
OTHERS |
Dimension |
40*90*100mm(W*H*D) |
Weight |
0.3Kg |
Packing |
42pcs/carton/13.6kg/0.82CUFT |
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Contact us for more details.