LEYU DR-15-12 single type smpsdin rail switching power supply
Product Description
Features:
1.Universal AC input /Full range
2.Protections:Short cricuit /Overload /Over voltage
3.Cooling by free air convection
4.100% full load burn-in test
5.2 years warranty
SPECIFICATIONS |
OUTPUT |
Model |
DR-15-5 |
DR15-12 |
DR-15-15 |
DR-15-24 |
DC Voltage |
5V |
12V |
15V |
24V |
Rated Current |
2.4A |
1.25A |
1A |
0.63A |
Current Range |
0-2.4A |
0-1.25A |
0-1A |
0-0.63A |
Rated Power |
12W |
15W |
15W |
15.2W |
Ripple & Noise |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
Voltage Adj. Range |
4.75-5.5V |
10.8-13.2V |
13.5-16.5V |
21.6-26.4V |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
Line regulation |
±1% |
±1% |
±1% |
±1% |
Load regulation |
±1% |
±1% |
±1% |
±1% |
Setup, Rise, Hold Up Time |
1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load 70ms/230VAC 16ms/115VAC at full load |
INPUT |
Voltage Range |
85 ~ 264VAC 120 ~ 370VDC |
AC Current |
0.88A/115VAC 0.48A/230VAC |
Efficiency |
77% |
84% |
83.5% |
85% |
Inrush Current |
COLD START 35A/115VAC 65A/230VAC |
Over Load |
105%~160% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over Voltage |
5.75-6.75V |
13.8-16.2V |
17.25-20.25V |
27.6-32.4V |
ENVIRONMENT |
|
Working Temp., Humidity |
-20ºC~+60ºC; 20%~90% RH non-condensing |
Storage Temp., Humidity |
-40ºC~+85ºC; 10%~95%RH |
Temp. Coefficient |
±0.03%/ºC(0~50ºC) |
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes, Mounting: Compliance to IE60068-2-6 |
SAFETY |
Withstand Voltage |
I/P-O/P: 3KVAC |
Isolation Resistance |
I/P-O/P: 100M Ohms / 500VDC/ 25ºC/ 70%RH |
STANDARD |
Safety Standard |
Design refer to UL60950-1,TUV EN60950-1,EN50178 |
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2,EN61204-3, heavy industry level, criteria A |
OTHERS |
Dimension |
25*93*56mm(W*H*D) |
Weight |
0.1Kg |
Packing |
140pcs/15KG/0.92CUFT |
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |