SP-320-24 PFC function single output 320W power supply
Product Description
Features:
·Universal AC input/ full range
·Built-in active PFC function, PF>0.93
·100% full load burn-in test
·Protections: Short circuit/ Over load / Over voltage/ Over temperature
·Built-in constant current limiting circuit
·LED indicator for power on
·Remote ON-OFF control (Optional)
·Fixed switching frequency at PF: 67KHz PWM: 134 KHz
·2 years warranty
SPECIFICATIONS |
OUTPUT |
|
Model |
SP-320-5 |
SP-320-7.5 |
SP-320-12 |
SP-320-13.5 |
SP-320-15 |
SP-320-24 |
SP-320-27 |
SP-320-36 |
SP-320-48 |
DC Voltage |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
36V |
48V |
Rated Current |
55A |
40A |
25A |
22A |
20A |
13A |
11.7A |
8.8A |
6.7A |
Current Range |
0-55A |
0-40A |
0-25A |
0-22A |
0-20A |
0-13A |
0-11.7A |
0-8.8A |
0-6.7A |
Rated Power |
275W |
300W |
300W |
297W |
300W |
312W |
315.9W |
316.8W |
321.6W |
Ripple&Noise |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
220mVp-p |
240mVp-p |
DC Adjustment Range |
±10% |
±20% |
-16%,+10% |
±11% |
-10%,+20% |
-16%,+10% |
-4%,+18% |
-15%,+17% |
-15%,+17% |
Voltage Tolerance |
±2% |
±2% |
±2% |
±2% |
±2% |
±1% |
±1% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Setup,Rise,Hold Up Time |
800ms,50ms,16ms/230VAC2500ms,50ms,16ms/115VAC at full load |
Voltage Range |
88~264VAC120~370VDCfrequency:47~63 Hz |
AC Current |
4A/115 VAC2A/230VAC |
Power Factor |
PF>0.95/230VAC,PF>0.98/115VAC at full load |
Efficiency |
79% |
83% |
86% |
86% |
86% |
87% |
88% |
87% |
89% |
Inrush Current |
22A/115VAC40A/230VAC |
Leakage Current |
<1 mA/240VAC |
Over Load |
105%-150% |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over Voltage(V) |
115%~135% |
Protection type: Shut down o/p voltage, re-power on to recover |
Over Temp. |
TSW1 (Power transistor) When Temp. in 80±5 ºC(70ºC±5 ºC5V), shut down o/p voltage, |
Temp.<65±5 ºC (55ºC±5 ºC5V), O/I auto-recovery. |
Working Temp.Humidity |
-20ºC~+65ºC; 20%~90 %RH |
Storage Temp.Humidity |
-40ºC~+85ºC; 10%~95 %RH |
Temp.Coefficient |
±0.03%/ºC(0~50ºC) |
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
Withstand Voltage |
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC |
Safety Standard |
Design refer to UL1950,TUV EN60950 |
EMCStandard |
Designrefer toEN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
Dimension |
215*115*50mm (L*W*H) |
Weight |
1.1Kg/pc |
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. |
3. Tolerance: includes set up tolerance, line regulation and load regulation. |
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Shirley Contact information
Any questions
please be free to contact Shirley at :