Output Type: | Single |
---|---|
Warranty: | 2 Years |
Output Power: | 101 - 200W |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
SPECIFICATIONS |
|||
OUTPUT |
|
||
Model |
DR-120-12 |
DR-120-24 |
DR-120-48 |
DC Voltage |
12V |
24V |
48V |
Rated Current |
10A |
5A |
2.5A |
Current Range |
0-10A |
0-10A |
0-2.5A |
Rated Power |
120W |
120W |
120W |
Ripple & Noise |
80mVp-p |
80mVp-p |
100mVp-p |
Voltage Adj. Range |
12-14V |
24-28V |
48-53V |
Voltage Tolerance |
±2% |
±1% |
±1% |
Setup, Rise Time |
500ms,70ms/230VAC 500ms,70ms/115VAC at full load |
||
Hold Up Time |
36ms/230VAC 32ms/115VAC at full load |
||
INPUT |
|
||
Voltage Range |
88~132VAC/176~264VAC selected by switch 47~63Hz; 248~370VDC |
||
AC Current |
2.6A/115V 1.6A/230V |
||
Efficiency |
80% |
84% |
85% |
Inrush Current |
Cold start 20A/115V 40A/230V |
||
Leakage Current |
<3.5mA/240VAC |
||
PROTECTION |
|
||
Over Load |
105%~150% |
||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
|||
Over Voltage |
120%~135% |
||
Protection type: Shut down o/p voltage, re-power on to recover |
|||
Over Temp. |
85°C±5°C(TSW1) |
90°C±5°C(TSW1) |
90°C±5°C(TSW1) |
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
|||
ENVIRONMENT |
|
||
Working Temp., Humidity |
-10°C~+60°C; 20%~90%RH |
||
Storage Temp., Humidity |
-20°C~+85°C; 10%~95%RH |
||
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
||
SAFETY |
|
||
Withstand Voltage |
I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
||
STANDARD |
|
||
Safety Standard |
Design refer to UL508,UL60950-1,TUV EN60950-1 |
||
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2) |
||
OTHERS |
|
||
Dimension |
65.5*125.2*100mm(L*W*H) |
||
Weight |
0.76Kg |
||
Packing |
35pcs/26kg/carton |
Suppliers with verified business licenses