Output Type: Single
Warranty: 2 Years
Output Power: 1 - 50W
Input Voltage: 110-220V
Connection Mode: Series Switching Power Supply
Starting Mode: Separate-excited Switching Power Supply
Samples:
US$ 15.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
HDR-60-15
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
Two-way Transmission
Modulation System
PWM
Certification
CE
Brand
Leyu
Transport Package
Carton
Specification
53*90*54.5mm(L*W*H)
Trademark
LEYU
Origin
China, Zhejiang
HS Code
8504401990
Production Capacity
6000PCS/Month

Product Description

60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS
Model HDR-60-5 HDR-60-12 HDR-60-15 HDR-60-24 HDR-60-48
DC Voltage 5V 12V 15V 24V 48V
Rated Current 6.5A 4.5A 4A 2.5A 1.25A
Current Range 0 ~ 6.5A 0 ~ 4.5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.25A
Rated Power 32.5W 54W 60W 60W 60W
Ripple & Noise (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p
Voltage Adj. Range 5.0 ~ 5.5V 10.8 ~ 13.8V 13.5 ~ 18V 21.6 ~ 29V 43.2 ~ 55.2V
Voltage Tolerance Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Load Regulation ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Setup, Rise Time 500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load
Hold Up Time (Typ.) 30ms/230VAC 12ms/115VAC at full load
Voltage Range 85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational )
Frequency Range 47 ~ 63Hz
Efficiency (Typ.) 85% 88% 89% 90% 91%
AC Current (Typ.) 1.2A/115VAC 0.8A/230VAC
Inrush Current (Typ.) COLD START 30A/115VAC 60A/230VAC
Over Load 105 ~ 160% rated output power
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed
Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed
Over Voltage 5.75 ~ 6.75V 14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V 56.5 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
Working Temp. -30 ~ +70ºC (Refer to "Derating Curve")
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85ºC, 10 ~ 95% RH non-condensing
Temp. Coefficient ±0.03%/ºC (0 ~ 50ºC) RH non-condensing
Vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
Operating Altitude 2000 meters
Safety Standards UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to EN62368-1
Withstand Voltage I/P-O/P:4KVAC
Isolation Resistance I/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH
MTBF 927.6K hrs min. MIL-HDBK-217F (25ºC)
Dimension 52.5*90*54.5mm (W*H*D)
Packing 190g;60pcs/12.4Kg/0.97CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies."
5. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft).
 
60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS60W DC 15V DIN Rail Power Supply Adjustable Slim LED Switching Power Supply 24V SMPS