Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 7.1/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SPECIFICATIONS | ||||
OUTPUT | ||||
Model | MS-50-5 | MS-50-12 | MS-50-15 | MS-50-24 |
DC Voltage | 5V | 12V | 15V | 24V |
Rated Current | 10A | 4.2A | 3.4A | 2.1A |
Current Range | 0-10A | 0-4.2A | 0-3.4A | 0-2.1A |
Rated Power | 50W | 50.4W | 51W | 50.4W |
Ripple & Noise | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Voltage Adj. Range | +10,-5% | ±10% | ±10% | ±10% |
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% |
Inlet Stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Stability | ±1% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise, Hold Up Time | 200s,100ms,30ms at full load | |||
Voltage Range | 100~240VAC 47~63Hz; 240~370VDC | |||
AC Current | 1.3A/115V 0.65A/230V | |||
Efficiency | 75% | 78% | 78% | 82% |
Inrush Current | Cold-start current 18A/115V 36A/230V | |||
Leakage Current | <0.5mA/240VAC | |||
Over Load | 105%~150% | |||
Protection type: Fold back current limiting Reset: auto recovery | ||||
Working Temp., Humidity | -10ºC~+60ºC(Refer to output derating curve),20%~90%RH | |||
Storage Temp., Humidity | -20ºC~+85ºC,10%~95%RH | |||
Temp. Coefficient | ±0.03%/ºC(0~50%) | |||
Vibration | 10~500Hz,2G 10min,/1cycle,Period for 60min,each axes | |||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||
Safety Standard | Meet UL1012 requirement(Not apply for the mark) | |||
Dimension | 110*72*35mm(L*W*H) | |||
Weight | 0.35Kg | |||
NOTE | ||||
1.The testing condition for the parameter above is: 230VAC input, rated load, 25ºC70% RH.Humidity. 2.Error.include the setting error,line stability and load stability. 3.Wave test:adopting "A12" double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. |