Dual output 55w 27.6v 5v ups power supply battery charger function
55W Dual Output with Battery Charger (UPS Function) ADD-55 series
Features:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low protections
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45 KHz
2 years warranty
SPECIFICATION |
MODEL |
ADD-55A |
ADD-55B |
OUTPUT |
|
|
Output number |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
DC voltage |
13.8V |
5V |
13.4V |
27.6V |
5V |
26.5V |
Rated Current |
2.5A |
3A |
0.23A |
1.3A |
3A |
0.16A |
Current Range |
0~3.5A |
0~4A |
-------- |
0~2A |
0~4A |
-------- |
Rated Power |
52.58W |
55.12W |
Ripple & Noise |
100mVp-p |
100mVp-p |
-------- |
150mVp-p |
150mVp-p |
-------- |
Voltage Adj. Range |
CH1:12~14.5V |
CH1:24~29V |
Voltage Tolerance |
±1.0% |
±3.0% |
-------- |
±1.0% |
±3.0% |
-------- |
Line Regulation |
±1.0% |
±0.5% |
-------- |
±1.0% |
±0.5% |
-------- |
Load Regulation |
±1.0% |
±0.5% |
-------- |
±1.0% |
±0.5% |
-------- |
Setup, Rise Time |
800ms,50ms/230VAC 1600ms,50ms/115VAC at full load |
Hold Up Time |
80ms/230VAC 16ms/115VAC at full load |
Voltage Range |
88~264VAC 47~63Hz; 124~370VDC |
AC Current |
1.6A/115VAC 1A/230VAC |
Efficiency |
71% |
74% |
Inrush Current |
Cold start 20A/115VAC 40A/230VAC |
Leakage Current |
<1mA /240VAC |
Over Load |
105~150% rated output power |
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse |
Over Voltage |
CH1:14.49~18.63V |
CH2:28.98~37.26V |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
Battery Low |
9.5~11V |
20~22V |
Working Temp. |
-10~+60ºC (Refer to "Derating Curve") |
Working Humidity |
20~90%RH non-condensing |
Storage Temp., Humidity |
-20~+85ºC,10~95%RH |
Temp. Coefficient |
±0.03%/ ºC(0~50ºC )on CH1 output |
Vibration |
10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes |
Safety Standards |
Design refer to UL60950-1, TUV EN60950-1 |
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
Isolation Resistance |
I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25ºC /70%RH
|
EMC Emission |
Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3
|
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A
|
Dimension |
159*97*38mm(L*W*H) |
Weight |
0.57Kg |
Packing |
24pcs/13.7Kg/0.75CUFT |
NOTE |
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |