60w 5v 12v -5v -12v common ground four way output dc regulated power supply Q-60
SPECIFICATIONS |
OUTPUT |
|
Model |
Q-60B |
Q-60C |
Q-60D |
Output number |
CH1 |
CH2 |
CH3 |
CH4 |
CH1 |
CH2 |
CH3 |
CH4 |
CH1 |
CH2 |
CH3 |
CH4 |
DC Voltage |
5V |
12V |
-5V |
-12V |
5V |
15V |
-5V |
-15V |
5V |
12V |
24V |
-12V |
Rated Current |
5.5A |
2A |
0.5A |
0.5A |
5.5A |
1.5A |
0.5A |
0.5A |
4A |
1A |
1A |
0.5A |
Current Range |
0.5-8A |
0.1-3A |
0-1A |
0-1A |
0.5-8A |
0.1-3A |
0-1A |
0-1A |
0.5-8A |
0.1-3A |
0.1-1.5A |
0-1A |
Rated Power |
60W |
60W |
60W |
60W |
60W |
60W |
60W |
60W |
60W |
62W |
62W |
62W |
Ripple & Noise |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
150mVp-p |
120mVp-p |
Voltage Adj. Range |
CH1: -5%, +10% |
CH1: -5%, +10% |
CH1: -5%, +10% |
Voltage Tolerance |
±2% |
±6% |
±5% |
±5% |
±2% |
8% |
±5% |
±5% |
±2% |
±6% |
8% |
±5% |
-4% |
-4% |
Setup,Rise,Hold Up Time |
1600ms,20ms,12ms/115VAC800ms,20ms, 60ms/230VAC at full load |
|
|
INPUT |
|
Voltage Range |
85~264VAC47-63Hz; 120~370VDC |
AC Current |
2A/115V0.8A/230V |
Efficiency |
70% |
72% |
75% |
Inrush Current |
Cold start 18A/115V36A/230V |
Leakage Current |
<1mA/240VAC |
|
|
PROTECTION |
|
Over Load |
105%~150%/115VAC |
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed |
Over Voltage |
5V:115%~135% |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|
|
ENVIRONMENT |
|
Working Temp., Humidity |
-10ºC~+60ºC; 20%~90%RH |
Storage Temp., Humidity |
-20ºC~+85ºC; 10%~95%RH |
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|
|
SAFETY |
|
Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
|
|
STANDARD |
|
Safety Standard |
Design refer to UL60950 |
EMC Standard |
Design refer to EN55022,EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204 |
|
|
OTHERS |
|
Dimension |
159*97*38mm(L*W*H) |
Weight |
0.56Kg |
Packing |
24pcs/14.4Kg/0.75CUFT |
|
|
NOTE |
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1μ &47μparallel capacitor. |
3.Tolerance: includes set up tolerance, line regulation and load regulation. |
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Product Description