350W 5V 60A AC to DC SMPS 300W Power Supply for CCTV
|
Still deciding? Get samples of $ !
Order Sample
|
Product Details
| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 2 Years |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Manufacturer/Factory & Trading Company
360° Virtual Tour
Secured Trading Service
Diamond Member Since 2011
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High Repeat Buyers Choice
Flexible Customization
Standardized Supplier Management
100% Finished Products Inspection
More than 50% of buyers repeatedly choose the supplier
The supplier provides Flexible customization services for your Personalized requirements
The company established and implemented an effective suppliers' assessment procedure and corrective & preventive actions mechanism
The supplier inspects 100% of finished products.
Sign In to see all verified strength labels (23)
Find Similar Products
Basic Info.
- Model NO.
- LRS-350-5
- Output Power
- 301 - 400W
- Input Voltage
- 110V/220V
- Connection Mode
- Series Switching Power Supply
- Starting Mode
- Self-excited Switching Power Supply
- Voltage Regulating Mode
- Frequency Modulation Type
- Power Supplying System
- Terminal Power Distribution Equipment
- Energy Transmission
- One-way Transmission
- Modulation System
- PWM
- Certification
- CE, RoHS, ISO
- Brand
- Leyu
- Color
- Sliver
- MOQ
- 1 PC
- OEM
- Accept
- Weight
- 0.76kg
- Efficiency
- 83.5%
- Output
- 5VDC
- Input
- 90 ~ 132VAC / 180 ~ 264VAC Selected by Switch
- Application1
- LED Lighting
- Application2
- Electrical Equipment
- Application3
- Industrial Control
- Transport Package
- Carton Packing
- Specification
- 215*115*30mm (L*W*H)
- Trademark
- LEYU
- Origin
- China
- HS Code
- 8504401990
- Production Capacity
- 60000PCS Per Month
Packaging & Delivery
- Package Size
- 37.00cm * 25.00cm * 25.00cm
- Package Gross Weight
- 18.000kg
Product Description
350W Single Output Switching Power Supply LRS-350 series
Features:
AC input range selectable by switch
Withstand 300VAC surge input for 5 second
Protections: Short circuit / Overload / Over voltage/ Over temperature
Forced air cooling by bulit-in DC fan
Built-in cooling Fan ON-OFF control
LED indicator for power on
100% full load burn-in test
High operating temperature up to 70ºC
High efficiency, long life and high reliability
2 years warranty








Features:
AC input range selectable by switch
Withstand 300VAC surge input for 5 second
Protections: Short circuit / Overload / Over voltage/ Over temperature
Forced air cooling by bulit-in DC fan
Built-in cooling Fan ON-OFF control
LED indicator for power on
100% full load burn-in test
High operating temperature up to 70ºC
High efficiency, long life and high reliability
2 years warranty



| SPECIFICATION | |||||||
| OUTPUT | |||||||
| Model | LRS-350-3.3 | LRS-350-5 | LRS-350-12 | LRS-350-15 | LRS-350-24 | LRS-350-36 | LRS-350-48 |
| DC Voltage | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
| Rated Current | 60A | 60A | 29A | 23.2A | 14.6A | 9.7A | 7.3A |
| Current Range | 0~60A | 0~60A | 0~29A | 0~23.2A | 0~14.6A | 0~9.7A | 0~7.3A |
| Rated Power | 198W | 300W | 348W | 348W | 350.4W | 349.2W | 350.4W |
| Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
| Voltage Adj. Range | 2.97~3.6V | 4.5 ~ 5.5V | 10~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
| Voltage Tolerance | ±4.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±2.5% | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Setup, Rise Time | 1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load | ||||||
| Hold Up Time | 16ms/230VAC 12ms/115VAC at full load | ||||||
| Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC) | ||||||
| Frequency Range | 47 ~ 63Hz | ||||||
| Efficiency | 79.50% | 83.50% | 85% | 86% | 88% | 88.50% | 89% |
| AC Current | 6.8A/115VAC 3.4A/230VAC | ||||||
| Inrush Current | 60A/115VAC 60A/230VAC | ||||||
| Leakage Current | <2mA / 240VAC | ||||||
| Over Load | 110 ~ 140% rated output power | ||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
| Over Voltage | 3.8~4.45V | 5.75~6.75V | 13.8 ~ 16.2V | 18~21V | 28.8 ~ 33.6V | 41.4~46.8V | 55.2~ 64.8V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
| Over temperature | Hiccup mode, recovers automatically after fault condition is removed | ||||||
| Working Temp. | -20 ~ +70ºC (Refer to "derating curve") | ||||||
| Working Humidity | 20 ~ 90% RH non-condensing | ||||||
| Storage Temp.,Humidity | -40 ~ +85ºC, 10 ~ 95% RH | ||||||
| Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | ||||||
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
| Safety Standards | UL60950-1 approved | ||||||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | ||||||
| Dimension | 215*115*30mm (L*W*H) | ||||||
| Weight | 0.76Kg | ||||||
| Packing | 15pcs/carton/12.4kg/0.78CUFT | ||||||
| NOTE | |||||||
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |
|||||||






Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Switching power supply
- LRS series
- 350W 5V 60A AC to DC SMPS 300W Power Supply for CCTV
Related Categories
Hot Searches
More