60W Dual Output Switching Power Supply D-60 series
Features:
High efficiency, high reliability
Universal AC input /full range
100% full load burn-in test
Protections: Short circuit/ Over load/ Over voltage
LED indicator for power on
Cooling by free air convection
Fixed switching frequency at 54KHz
2 years warranty
Product Parameters
SPECIFICATIONS |
OUTPUT |
|
Model |
D-60A |
D-60B |
D-60C |
Output number |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
DC Voltage |
5V |
12V |
5V |
24V |
15V |
-15V |
Rated Current |
4A |
3A |
2A |
2A |
2A |
1.5A |
Current Range |
0.8-4A |
0.3-3A |
0.8-3A |
0.2-2A |
0.5-2A |
0.2-1.5A |
Rated Power |
56W |
58W |
60W |
Ripple & Noise |
80mVp-p |
100mVp-p |
80mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
Voltage Adj. Range |
CH1: -5%,+10% |
CH1: -5%,+10% |
CH1: -5%,+10% |
Voltage Tolerance |
±2% |
±6% |
±3% |
±5% |
±3% |
±5% |
Setup,Rise,Hold Up Time |
800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC at full load |
Voltage Range |
85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC |
AC Current |
1.8A/115V 0.9A/230V |
Efficiency |
74% |
76% |
78% |
Inrush Current |
Cold start 25A/115V 50A/230V |
Leakage Current |
<1mA/240VAC |
Over Load |
105%~150% rated output power |
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed |
Over Voltage |
CH1: 115%~135% |
Protection type: hiccup mode, auto-recovery after fault condition is removed |
Working Temp., Humidity |
-10ºC~+60ºC; 20%~90%RH |
Storage Temp., Humidity |
-20ºC~+85ºC; 10%~95%RH non-condensing |
Temp. Coefficient |
±0.03%/ºC(0~50ºC) |
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
Withstand Voltage |
I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
Safety Standard |
Design refer to UL1012, UL60950, EN60950 |
EMC Standard |
Design refer to EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 |
Dimension |
159*97*38mm(L*W*H) |
Weight |
0.55Kg |
Packing |
45pcs/25.5Kg/1.45CUFT |
NOTE |
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |