Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 20/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment methods: | |
---|---|
Support payment in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SPECIFICATIONS | |||
OUTPUT | |||
Model | DR-100-12 | DR-100-15 | DR-100-24 |
DC Voltage | 12V | 15V | 24V |
Rated Current | 7.5A | 6.5A | 4.2A |
Current Range | 0-7.5A | 0-6.5A | 0-4.2A |
Rated Power | 90W | 97.5W | 100.8W |
Ripple & Noise | 120mVp-p | 120mVp-p | 150mVp-p |
Voltage Adj. Range | 12-15V | 15-18V | 24-29V |
Voltage Tolerance | ±2% | ±1% | ±1% |
Line regulation | ±1% | ±1% | ±1% |
Load regulation | ±1% | ±1% | ±1% |
Setup, Rise Time | 2700ms,80ms/230VAC 2700ms,80ms/115VAC at full load | ||
Hold Up Time | 50ms/230VAC 18ms/115VAC at full load | ||
Voltage Range | 85~264VAC 47~63 Hz; 124~370VDC | ||
AC Current | 1.6A/115V 0.96A/230V | ||
Efficiency | 87% | 87% | 89% |
Inrush Current | Cold start 30A/115VAC 45A/230VAC | ||
Leakage Current | <1mA/240VAC | ||
Over Load | 105%~135% rated output power | ||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||
Over Voltage | 16-20V | 19-23V | 30-35V |
Protection type: Shut down o/p voltage, re-power on to recover | |||
Over Temp. | Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | ||
Working Temp., Humidity | -20ºC~+60ºC; 20%~90% RH non-condensing | ||
Storage Temp., Humidity | -40ºC~+85ºC; 10%~95%RH | ||
Vibration | 10~500Hz, 2G 10min./1cycle, 60min, each along X, Y, Z axes | ||
Withstand Voltage | I/P-O/P: 3KVAC | ||
Isolation Resistance | I/P-O/P>100M Ohms / 500VDC/25ºC/70%RH | ||
Safety Standard | Design refer to UL60950-1,TUV EN60950-1, EN50178 | ||
EMC Standard | EN61240-3,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2, EN61204-3,heavy industry level, criteria A | ||
Dimension | 100*93*56mm(L*W*H) | ||
Weight | 0.35Kg | ||
Packing | 36pcs/13.6Kg/0.89CUFT | ||
NOTE | |||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |