• 350W 12V 30A DC Thin Power Supply with Fan
  • 350W 12V 30A DC Thin Power Supply with Fan
  • 350W 12V 30A DC Thin Power Supply with Fan
  • 350W 12V 30A DC Thin Power Supply with Fan
  • 350W 12V 30A DC Thin Power Supply with Fan
  • 350W 12V 30A DC Thin Power Supply with Fan

350W 12V 30A DC Thin Power Supply with Fan

Output Type: Single
Warranty: 2 Years
Output Power: 301 - 400W
Samples:
US$ 16/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
350W 12V 30A DC Thin Power Supply with Fan pictures & photos
350W 12V 30A DC Thin Power Supply with Fan
US $13.5-15.8 / Piece
Min. Order: 1 Piece
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
LRS-350-12
Input Voltage
110V/220V
Connection Mode
Series Switching Power Supply
Starting Mode
Self-excited Switching Power Supply
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
One-way Transmission
Modulation System
PWM
Certification
CE, RoHS, ISO, CCC
Brand
Leyu
Color
Siliver
MOQ
1 PC
OEM
Accept
Rated Power
350W
Output
12V 30A
Weight
0.76kg
Transport Package
Box Packing
Specification
215*115*30mm (L*W*H)
Trademark
LEYU
Origin
China
HS Code
8504401990
Production Capacity
6000PCS/Month

Packaging & Delivery

Package Size
21.50cm * 11.50cm * 3.00cm
Package Gross Weight
0.900kg

Product Description

350W 12V 30A DC Thin Power Supply with Fan350W 12V 30A DC Thin Power Supply with Fan350W 12V 30A DC Thin Power Supply with Fan350W 12V 30A DC Thin Power Supply with Fan
SPECIFICATION  
OUTPUT  
Model LRS-350-3.3 LRS-350-5 LRS-350-12 LRS-350-15 LRS-350-24 LRS-350-36 LRS-350-48
DC Voltage 3.3V 5V 12V 15V 24V 36V 48V
Rated Current 60A 60A 29A 23.2A 14.6A 9.7A 7.3A
Current Range 0~60A 0~60A 0~29A 0~23.2A 0~14.6A 0~9.7A 0~7.3A
Rated Power 198W 300W 348W 348W 350.4W 349.2W 350.4W
Ripple & Noise 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
Voltage Adj. Range 2.97~3.6V 4.5 ~ 5.5V 10~ 13.8V 13.5~18V 21.6~28.8V 32.4~39.6V 43.2~52.8V
Voltage Tolerance ±4.0% ±3.0% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±2.5% ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time 1300ms, 50ms/230VAC   1300ms, 50ms/115VAC at full load
Hold Up Time 16ms/230VAC   12ms/115VAC at full load
   
INPUT  
Voltage Range 90 ~ 132VAC / 180 ~ 264VAC selected by switch   254 ~ 370VDC (switch on 230VAC)
Frequency Range 47 ~ 63Hz
Efficiency 79.5% 83.5% 85% 86% 88% 88.5% 89%
AC Current 6.8A/115VAC  3.4A/230VAC
Inrush Current 60A/115VAC   60A/230VAC
Leakage Current <2mA / 240VAC
   
PROTECTION  
Over Load 110 ~ 140% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 3.8~4.45V 5.75~6.75V 13.8 ~ 16.2V 18~21V 28.8 ~ 33.6V 41.4~46.8V 55.2~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over temperature Hiccup mode, recovers automatically after fault condition is removed
   
ENVIRONMENT  
Working Temp. -20 ~ +70ºC (Refer to "derating curve")
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85ºC, 10 ~ 95% RH
Temp. Coefficient ±0.03%/ºC (0 ~ 50ºC)
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
   
SAFETY  
Safety Standards UL60950-1 approved
Withstand Voltage I/P-O/P:3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH
   
OTHERS  
Dimension 215*115*30mm (L*W*H)
Weight 0.76Kg
Packing 15pcs/carton/12.4kg/0.78CUFT
   
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.