Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
CE Rohs approved NES-150-24 150w 24v 6.5a power supply unit
150W Single Output Switching Power Supply NES-150 series
Features:
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
2 years warranty
SPECIFICATION | ||||||||
OUTPUT | ||||||||
Model | NES-150-5 | NES-150-7.5 | NES-150-9 | NES-150-12 | NES-150-15 | NES-150-24 | NES-150-48 | NES-150-50 |
DC Voltage | 5V | 7.5V | 9V | 12V | 15V | 24V | 48V | 50v |
Rated Current | 26A | 20A | 16.7A | 12.5A | 10A | 6.5A | 3.3A | 3A |
Current Range | 0~26A | 0~20A | 0~16.7A | 0~12.5A | 0~10A | 0~6.5A | 0~3.3A | 0-3A |
Rated Power | 130W | 150W | 150W | 150W | 150W | 156W | 158.4W | 150W |
Ripple & Noise | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | 200mVp-p |
Voltage Adj. Range | 4.75 ~5.5V | 7.13 ~ 8.3V | 8.55 ~ 9.9V | 11.4 ~ 13.5V | 14.25 ~ 16.5V | 22.8 ~ 27.6V | 45.6 ~ 52.8V | 45~55V |
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise Time | 800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | |||||||
Hold Up Time | 24ms/230VAC 20ms/115VAC at full load | |||||||
Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 373VDC | |||||||
Frequency Range | 47 ~ 63Hz | |||||||
Efficiency | 78% | 80% | 83% | 83% | 83% | 86% | 86% | 86% |
AC Current | 3A/115VAC 2A/230VAC | |||||||
Inrush Current | Cold Start 45A/230VAC | |||||||
Leakage Current | <2mA / 240VAC | |||||||
Over Load | 110 ~ 150% rated output power | |||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||
Over Voltage | 5.75 ~ 6.75V | 8.6 ~ 10.1V | 10.4 ~ 12.2V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | 63.2~74.2V |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||
Working Temp. | -20 ~ +60ºC (Refer to output load derating curve) | |||||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||||
Storage Temp., Humidity | -40 ~ +85ºC, 10 ~ 95% RH | |||||||
Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | |||||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||
Safety Standards | UL60950-1, CB(IEC60950-1),CCC GB4943 approved | |||||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | |||||||
EMI Conduction & Radiation | Compliance to EN55022 (CISPR22) Class B,GB9254 CLASS B | |||||||
Harmonic Current | Compliance to EN61000-3-2,-3,GB17625.1 | |||||||
EMC Immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, heavy industry level, criteria A | |||||||
Dimension | 199*98*38mm (L*W*H) | |||||||
Weight | 0.7Kg | |||||||
Packing | 20pcs/carton/15kg/0.72CUFT | |||||||
NOTE | ||||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |
contact us
>>Service |
|
1. Low MOQ: It can meet your promotional business very well
2. OEM/ODM Accepted: We can produce any your design
3. Good Service: We treat clients as friend
4. Good Quality: We have strict quality control system. Good reputation in the market
5. Fast & Cheap Delivery: We have big discount from forwarder (Long contract)
6. Professional Service: From inquiry ->make sample ->start order ->inspecation ->delivery
>>Contacting |
|
Miss Cindy Chen