| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 2 Years |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

MODEL | WDR-120-12 | WDR-120-24 | WDR-120-48 | |
OUTPUT | DC VOLTAGE | 12V | 24V | 48V |
RATED CURRENT | 10A | 5A | 2.5A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | 0 ~ 2.5A | |
RATED POWER | 120W | 120W | 120W | |
RIPPLE & NOISE | 120mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 12 ~ 15V | 24 ~ 29V | 48 ~ 58V | |
VOLTAGE TOLERANCE | ±1.5% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE, HOLD UP TIME | 2000ms, 70ms, 50ms/400VAC 2000ms, 70ms, 10ms/230VAC at full load | |||
INPUT | VOLTAGE RANGE | 180 ~ 550VAC 254 ~ 780VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
EFFICIENCY (Typ.) | 89.5% / 400V | 91% / 400V | 92% / 400V | |
AC CURRENT | 0.7A/400VAC 1.2A/230VAC | |||
INRUSH CURRENT (max.) | COLD START 50A | |||
LEAKAGE CURRENT | <3.5mA / 530VAC | |||
PROTECTION | OVERLOAD | 105 ~ 130% rated output power | ||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 16 ~ 18V | 31 ~ 37V | 60 ~ 67V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||
FUNCTION | DC OK SIGNAL | Relay contact rating(max.) : 30V / 1A resistive | ||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70°C (Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |||
VIBRATION | Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6 | |||
SAFETY & EMC | SAFETY STANDARDS | UL508, AS/NZS 62368.1, EAC TP TC 004 approved, IEC62368-1 CB approved by SIQ.(meet EN60204-1) | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH | |||
EMC EMISSION | Compliance to EN55032 (CISPR32), EN61204-3 Class B, EAC TP TC 020 | |||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 | |||
OTHERS | MTBF | 268K hrs min. MIL-HDBK-217F (25°C) | ||
DIMENSION | 40*125.2*113.5mm (W*H*D) | |||