SPECIFICATIONS |
OUTPUT |
|
Model |
LPV-60-5 |
LPV-60-12 |
LPV-60-15 |
LPV-60-24 |
LPV-60-36 |
LPV-60-48 |
DC Voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Rated Current |
8A |
5A |
4A |
2.5A |
1.67A |
1.25A |
Current Range |
0-8A |
0-5A |
0-4A |
0-2.5A |
0-1.67A |
0-1.25A |
Rated Power |
40W |
60W |
60W |
60W |
60W |
60W |
Ripple & Noise |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
Voltage Tolerance |
±8% |
±5% |
Line Regulation |
±1% |
Load Regulation |
±6% |
±2% |
Setup, Rise Time |
500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load(for 5-36V) 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load(for 48V) |
Hold Up Time |
50ms/230VAC 16ms/115VAC at full load |
Voltage Range |
90~264VAC 47-63Hz; 127~370VDC |
AC Current |
1.2A/115V 1A/230V |
Efficiency |
76% |
83% |
83% |
86% |
86% |
86% |
Inrush Current |
Cold Start 60A at 230VAC |
Leakage Current |
0.25mA/240VAC |
Over Load |
110-150% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage |
5.75-6.75V |
13.8-16.2V |
17.25-20.25V |
27.6-32.4V |
41.4-48.6V |
55.2-64.8V |
Protection type: Shut down o/p voltage, re-power on to recover |
Working Temp.Humidity |
-30 ~ +70ºC (Refer to "Derating Curve") |
Storage Temp.Humidity |
-40ºC~+80ºC; 10%~95%RH |
Temp.Coefficient |
±0.03%/ºC(0~50ºC) |
Vibration |
10~500Hz,2G 10min,/1cycle,period for 60min,each along X,Y,Z axes |
Withstand Voltage |
I/P-O/P:3KVAC |
Isolation Resistance |
I/P-O/P>100M Ohms / 500VDC / 25ºC / 70% RH |
Safety Standard |
UL879(expect for LPV-60-5), UL1310(expect for LPV-60-5), CSA C22.2 No.207-M91(expect for LPV-60-5, LPV-60-48), IP67, IEC60950-1:2005+A2:2013 approved; design refer to TUV EN60950-1 |
EMC Standard |
EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A |
Dimension |
162.5*42.5*32mm(L*W*H) |
Weight |
0.4kg;32pcs/13.8kg/0.56CUFT |
NOTE |
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Derating may not be needed under low input voltage. Please check the static characteristics for more details. |