| SPECIFICATION |
| OUTPUT |
|
|
|
| MODEL |
ADD-155A |
ADD-155B |
ADD-155C |
| Output number |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
| DC voltage |
13.8V |
5V |
13.3V |
27.6V |
5V |
27.1V |
54 V |
5 V |
53.5 V |
| Rated Current |
9.5A |
3A |
0.5A |
4.5A |
3A |
0.5A |
2.3A |
3A |
0.2A |
| Current Range |
0~10.5A |
0~3A |
-------- |
0~5A |
0~3A |
--------- |
0~2.5A |
0~3A |
--------- |
| Rated Power |
152.75W |
152.75W |
149.9W |
| Ripple & Noise |
150mVp-p |
100mVp-p |
-------- |
200mVp-p |
100mVp-p |
------- |
240mVp-p |
100mVp-p |
--------- |
| Voltage Adj. Range |
CH1:12~14.5V |
CH1:24~29V |
CH1:48~58V |
| Voltage Tolerance |
±2.0% |
±3.0% |
-------- |
±1.0% |
±3.0% |
-------- |
±1.0% |
±5.0% |
--------- |
| Line Regulation |
±1.0% |
±0.5% |
-------- |
±1.0% |
±0.5% |
-------- |
±1.0% |
±0.5% |
--------- |
| Load Regulation |
±1.0% |
±2.0% |
-------- |
±1.0% |
±2.0% |
-------- |
±1.0% |
±2.0% |
--------- |
| Setup, Rise Time |
1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load |
| Hold Up Time |
24ms/230VAC 20ms/115VAC at full load |
| INPUT |
|
| Voltage Range |
88~264VAC 47~63Hz; 124~370VDC |
| AC Current |
2.5A/115VAC 1.5A/230VAC |
| Efficiency |
78% |
81% |
81% |
| Inrush Current |
Cold start 20A/115VAC 40A/230VAC |
| Leakage Current |
<1mA /240VAC |
| PROTECTION |
|
| Over Load |
CH1,CH2:105 ~ 135% CH3:0.51 ~ 0.9A rated output power |
| Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse |
| Over Voltage |
CH1:15.87~18.63V |
CH1:31.74~37.26V |
CH1:62.1~72.9V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed |
| Battery Low |
10V±0.8V |
19.5V±1.5V |
39V±2V |
| ENVIRONMENT |
|
| Working Temp. |
-10~+60ºC (Refer to "Derating Curve") |
| Working Humidity |
20~90%RH non-condensing |
| Storage Temp., Humidity |
-20~+85ºC,10~95%RH |
| Temp. Coefficient |
±0.03%/ ºC(0~50ºC )on CH1 output |
| Vibration |
10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes |
| SAFETY &EMC |
|
| Safety Standards |
Design refer to UL60950-1, TUV EN60950-1 |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25ºC /70%RH |
| EMC Emission |
Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 |
| EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A |
| OTHERS |
|
| Dimension |
119*110*50mm(L*W*H) |
| Weight |
1Kg |
| Packing |
16pcs/16Kg/0.95CUFT |
| NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |